Sikafloor® MultiDur ES-14
Sikafloor® MultiDur ES-14 is a smooth, coloured, rigid flooring system based on epoxy resins.
- Good chemical and mechanical resistance
- Good wear and abrassion resistance
- Easy application
- Liquid proof
- Gloss finish
- Easy cleanability
- Colour options
System Structure
1
Primer
2
Top Coat
Usage
- For concrete and cement screeds with normal up to medium wear
- For office, indoor area, storage room, plant room
Advantages
- Good chemical and mechanical resistance
- Good wear and abrassion resistance
- Easy application
- Liquid proof
- Gloss finish
- Easy cleanability
- Colour options
Packaging
Please refer to the individual Product Data Sheet
Appearance
Gloss finish
System Details
System Structure
Sikafloor® MultiDur ES-14
Layer | Product |
1. Primer | Sikafloor®-156 |
2. Top coat | Sikafloor®-264 |
Composition
Epoxy
Nominal Thickness
0.6–0.8 mm
Shelf Life
Please refer to the individual Product Data Sheet
Storage Conditions
Please refer to the individual Product Data Sheet
Shore D Hardness
~ 76 (7 days / +23 °C) | (DIN 53 505) |
Abrasion Resistance
~ 54 mg (CS 17/1000/1000) (7 days / +23 °C) | (ASTMD4060-10) |
Tensile Adhesion Strength
> 1.5 N/mm² (failure in concrete) | (ISO 4624) |
Chemical Resistance
Please refer to the chemical resistance chart of Sikafloor®- 264
Thermal Resistance
Exposure* | Dry heat |
Permanent | +50 °C |
Short-term max. 7 d | +80 °C |
Short-term max. 12 h | +100 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional (steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Application
Product Temperature
Please refer to the individual Product Data Sheet
Ambient Air Temperature
+10 °C min. / +30 °C max.
Relative Air Humidity
80 % r.h. max.
Dew Point
Beware of condensation! The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.Substrate Temperature
+10 °C min. / +30 °C max.
Substrate Moisture Content
When performing application work with Sikafloor® MultiDur ES-14, the substrate moisture content must not exceed 4 % pbw measured by Tramex.Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-method. No rising moisture according to ASTM (Polyethylene-sheet).
Waiting Time / Overcoating
Before applying Sikafloor®-264 on Sikafloor®-156 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 3 days |
+20 °C | 12 hours | 2 days |
+30 °C | 8 hours | 1 day |
Before applying Sikafloor®-264 on Sikafloor®-264 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 30 hours | 3 days |
+20 °C | 24 hours | 2 days |
+30 °C | 16 hours | 1 day |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~ 72 hours | ~ 6 days | ~ 10 days |
+20 °C | ~ 24 hours | ~ 4 days | ~ 7 days |
+30 °C | ~ 18 hours | ~ 2 days | ~ 5 days |
Note: Times are approximate and will be affected by changing ambient conditions.
Consumption
Sikafloor® MultiDur ES-14 system
Coating System | Product | Consumption |
Primer | 1–2 × Sikafloor®-156 | 1–2 × 0.35–0.55 kg/m² |
Top coat | 1–2 × Sikafloor®-264 | 1–2 × 0.25–0.3 kg/m² for each layer |
CLEANING
Please refer to the Method Statement Sikafloor®‐ Cleaning Regime