APPLICATION
Strictly follow installation procedures as defined in method statements, application manuals and working instructions which must always be adjusted to the actual site conditions.
Reference must be made to the Sika Method Statement: Protective Coatings
Note: Confirm waiting / overcoating times of any previous mortars, primers or coats is achieved before applying subsequent coats. (Refer to waiting / overcoating time in Application Information)
Note: Confirm product application conditions: substrate moisture content, substrate, air and product temperatures, relative humidity and dew point.
Note: Make sure the application area is well ventilated during application and drying.
Note: To prevent air bubbles affecting the finish, do not 'over' brush, roller or spray.
Protective coating
Manual application
- Apply the Product evenly over the surface with a brush or short pile fleece roller at the required consumption.
- Control the layer thickness during application using a thickness gauge to achieve the required total dry film thickness.
- The coating must be continuous, pore free and to the required surface finish.
- Protect the Product from heavy rain or rain showers until dry to prevent surface damage.
- Apply additional coats as required.
Airless spray application
IMPORTANT
Do not use aerosol car body type spraying equipment
- Spray apply the product in a continuous cross-spray operation and at a speed to achieve a consistent thickness and the required surface finish.
- Control the layer thickness during application using a thickness gauge.
- The coating must be continuous, pore free and to the required surface finish.
- Protect the Product from heavy rain or rain showers until dry to prevent surface damage.
- Apply additional coats as required.