Sikagard®-552 W Aquaprimer
Waterborne primer for concrete protection coatings
Sikagard®-552 W Aquaprimer is a one-part waterborne adhesion promoting primer for water dispersed polymer paint coatings. Sikagard®-552 W Aquaprimer is part of a system that is in scope of the requirements of EN 1504-2 as a protective coating.
- Waterborne
- Water vapour permeable
- Good adhesion to concrete
- 1-part ready to use
Overview
Usage
The Product is used as a primer before the following products:- Waterborne concrete protection coatings
- Cementitious resurfacing mortars
- Untreated concrete
- Concrete treated with hydrophobic impregnations
- Existing firmly adhering waterborne coatings
- Fibre cement
- Leveling mortars
- Gypsum
- The Product may only be used by experienced professionals.
Advantages
- Waterborne
- Water vapour permeable
- Good adhesion to concrete
- 1-part ready to use
Packaging
Refer to the current price list for available packaging variations.
Colour
Cured appearance | Milky white liquid |
Product Details
APPROVALS / STANDARDS
CE marking and declaration of performance based on EN 1504-2:2004 Products and systems for the protection and repair of concrete structures — Surface protection systems for concrete — Coating
Chemical Base
Acrylate dispersion
Shelf Life
24 months from date of production
Storage Conditions
The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C. Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
~1.0 kg/l (at 20 °C)
Solid Content by Volume
20 %
System Structure
1 × Sikagard®-552 W Aquaprimer
Application
Product Temperature
Maximum | +35 °C |
Minimum | +8 °C |
Ambient Air Temperature
Maximum | +35 °C |
Minimum | +8 °C |
Relative Air Humidity
Maximum | 80 % |
Dew Point
Beware of condensation. The substrate and uncured applied product must be at least +3 °C above dew point to reduce the risk of condensation or blooming on the surface of the applied product. Low temperatures and high humidity conditions increase the probability of blooming.
Substrate Temperature
Maximum | +35 °C |
Minimum | +8 °C |
Substrate Moisture Content
Substrate | Test method | Moisture content |
Cementitious substrates | Calcium carbide method (CM-method) | ≤ 4 % |
No rising moisture (ASTM D4263, polyethylene sheet)
Waiting Time / Overcoating
PRIMER FOR COATING PRODUCTS
Waiting time before applying a waterborne coating:
| Temperature | Time |
| +8 °C | 12 hours |
| +20 °C | 5 hours |
| +35 °C | 2.5 hours |
When the application is over an existing coating, waiting time to overcoating is doubled.
PRIMER FOR CEMENT BASED RESURFACING PRODUCTS
When used as primer under resurfacing mortar apply the mortar while the primer is tacky. If the Product has dried out completely, re-apply 1 coat.
Consumption
0.10–0.12 kg/m² (8–10 m² per litre) dependent on the absorbency of the substrate.
APPLICATION INSTRUCTIONS
IMPORTANT
Strictly follow installation procedures
Strictly follow installation procedures as defined in Method Statements, application manuals and working instructions which must always be adjusted to the actual site conditions.
SUBSTRATE PREPARATION
EXPOSED CONCRETE WITHOUT EXISTING COATING
Preconditions
New concrete is at least 28 days old.
The substrate is clean, dry and free of all contaminants such as dirt, oil, grease, surface treatments and loose friable material which can reduce the adhesion of the coating.
- Prepare the substrate mechanically using suitable equipment such as abrasive blast cleaning or high pressure water jetting to achieve a textured surface profile suitable for the Product thickness and required coating adhesion values.
- Fill all surface defects, blowholes, cavities and pores using a pore filler (such as Sika MonoTop®-3020, Sikagard®-720 EpoCem® or Sikagard®-545 W Elastofill) to provide a defect free surface.
- For a cementitous pore filler, allow a curing time of at least 4 days before coating. If Sikagard®-545 W Elastofill or Sikagard®-720 EpoCem® is used, then coating can be applied within 24 hours.
EXPOSED CONCRETE WITH EXISTING COATING
- Test existing coatings to confirm their adhesion to the substrate and their compatibility.
As guidance, in the absence of any national standards or regulations, adhesion test average ≥ 0.8 N/mm2 with no single value below 0.5 N/mm2.
INADEQUATE ADHESION
- Completely remove existing coatings using suitable equipment and prepare the substrate as described in 'Exposed concrete without existing coating'.
ADEQUATE ADHESION
- Thoroughly clean the existing fully bonded coating surfaces of all contaminants using suitable equipment such as steam cleaning or high pressure water jetting.
- For a waterborne existing coating, use Sikagard®-552 W Aquaprimer as a primer.
- For a solvent-based existing coating, use Sikagard®-551 S Elastic Primer as a primer.
- If coating type is unknown, carry out compatibility and adhesion testing to determine which primer is most suitable.
IMPORTANT Wait at least 2 weeks before conducting the adhesion test. The adhesion test average must be ≥ 0.8 N/mm2 with no single value below 0.5 N/mm2
For more information refer to the Application of Sikagard® protective coatings.
APPLICATION
IMPORTANT
Climate conditions during application
The climate conditions during application and curing of the Product can affect the final performance achieved.
Application at temperatures below the stated minimum application temperature may reduce adhesion.
- Do not apply the Product if rain is expected.
- Allow enough time for the substrate to dry after rain or other inclement conditions.
- Do not apply the Product at temperatures below the stated minimum application temperature.
- Shake the Product for 30 seconds prior to application.
- Apply the Product to the substrate using a brush, roller or airless spray equipment.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened material can only be removed mechanically.